If there is a problem with the operation of the grill an error may be detected and presented on the controller screen and Trimal Aus App. The following table is a summary of the errors.
For any electrical component errors, their operaiton can be checked using the test function in the controller menu.
| Error | Error Problem, Grill Action & Solution |
|---|---|
| ERROR 21 Grill temperature sensor | Problem: No signal from grill temperature sensor. Action: Fans on 10 minutes, then grill power off. Solution: Replace temperature sensor. Temporarily use food probe 1 in place or normal grill sensor: Go to MENU > SETTINGS > Grill Temperature Probe > Probe 1. More instructions here |
| ERROR 22 Ambient temperature sensor | Problem: No signal from ambient temperature sensor. Action: Continue normal operation, but assumes 30℃ ambient temperature. Solution: Replace temperature sensor. |
| ERROR 24 Wood pellet sensor | Problem: No signal from wood pellet sensor. Action: Continue normal operation, but hide pellet sensor icon on screen and App. Solution: Check plug connection. Replace if faulty. Pellet Sensor Repair Guide |
| ERROR 31 Auger motor failure | Problem: Auger motor is not using power when on. Action: Fans on 10 minutes, then grill power off. Solution: Check for jam. If dead, replace auger motor. How to clear a jam. |
| ERROR 32 Inner fan motor failure | Problem: Inner fan is not using power when on. Action: Outer fan on 10 minutes, then grill power off. Solution: Replace inner fan. |
| ERROR 33 Outer fan motor failure | Problem: Outer fan is not using power when on. Action: Grill power immediately off. Solution: Replace outer fan. |
| ERROR 41 Pellet ignitor failure | Problem: Pellet ignitor is not using power when on Action: Fans on 10 minutes, then grill power off. Solution: Replace pellet ignitor. Turn off pellet ignitor and manually light fire until replaced. Pellet Ignitor Repair Guide |
| ERROR 42 Heating element failure | Problem: Heating element is not using power when on Action: Heating element will not be used. All modes that use wood pellet heat can operate as normal. Solution: Replace heating element. |
| ERROR 51 Grill High Temperature | Problem: Temperature exceeded 340℃ for >1minute Action: Fans on 10 minutes, then grill power off. Solution: Check grill operation. |
| ERROR 52 Flame Out | Problem: Temperature dropping; likely fire is out – or lid has been left open for too long. Action: Fans on 10 minutes, then grill power off. Solution: Do a visual check of the fire grates to ensure they are sitting correctly, no wood pellet build or ash accumulation. |
| ERROR 53 No Fire Established | Problem: Temperature not rising; likely no fire established, or lid left open during fire-up; Grill already very hot. Action: Fans on 10 minutes, then grill power off. Solution: Do a visual check of the fire grates to ensure they are sitting correctly, no wood pellet build or ash accumulation. If grill was already hot, open the lid for several minutes before starting the fire up process and closing the lid again – allowing a temperature rise to occur and the controller to register the fire as lit. |
Contact us for support.